Book Nook Join Book Nook

Transactions of the Canadian Society of Civil EngineersBook 10 of 20

Transactions of the Canadian Society of Civil Engineers Volume 10

Canadian Society of Civil Engineers

This historic book may have numerous typos and missing text. Purchasers can download a free scanned copy of the original book (without typos) from the publisher. Not indexed. Not illustrated. 1896 Excerpt: ...would be perhaps the hardest thing to overcome in connection with the economical uso of compressed air. Mr. Barnett was not familiar with experience elsewhere in reheating Mr. J. D. the air. His own only covered five months. So far he had had no trouble. The flame did not touch the copper pipe. The copper was just as thin as he could get it, so that it would turn into a 2 inch coil. He could not tell the thickness of the pipe, but it had not burned out, and it had suffered nothing from internal corrosion, but the BB burner did not give a great deal of heat. He only raised the temperature o1" the air about 40 degrees, which was nothing liice what it was raised in Paris and other places where they have hid long experience. The speaker's heating appliance looked like a common tin lamp. It was not taller than a water pitcher. There was scarcely any expenso except making the coil out of the copper tube. The air was sensibly cold to the hand on entering the heating coil. You could just feel it nicely warm after leaving it. Its great advantage was that when the temperature was 20 below zero outside, the exhaust pipes and valves were not choked with ice. A great nuisance in trying to use these small motors extensively in a low temperature was the formation of ice; therefore, if for no other reason he would say: put a lamp on one of these small motors to get rid of that trouble, even if there were no thermodynamic advantage in its use. Prof. Galbraith said he thought it was to a great extent the same prof. J. question as arose in connection with the use of superheated steam, that seemed to be coming in now. The avoidance of cylinder condensation was a great object to bo served by the use of superheated steam, and he thought the main objection to its use on any ...

GenresHistory

58 pages, 2 editions

English edition · First published 2012 by Rarebooksclub.com · ISBN 9781130977981

Be the first to rate this book

Tap or drag across the stars

Editions

2 editions

English

  • Transactions of the Canadian Society of Civil Engineers Volume 10 · Rarebooksclub.com · 2012 · ISBN 9781130977981 This page
  • Transactions of the Canadian Society of Civil Engineers, Volume 10 · BiblioBazaar · 2016 · ISBN 9781354970584

Keep track of what you read

Book Nook is a free reading tracker with a 3D bookshelf, a reading timer, challenges with friends and a Reading Wrapped at the end of the year. Add Transactions of the Canadian Society of Civil Engineers Volume 10 to your shelf in one tap.

Join Book Nook Get the app